Access the BMC KVM Console from Brainsalt Hub
Open a remote keyboard-video-mouse (KVM) session to your Brainsalt server's Baseboard Management Controller (BMC) from the Brainsalt Hub Desktop App. The BMC gives you BIOS-level control of the server even when its operating system is not running.
The Hub opens the BMC's own web interface with the login already filled in. The KVM console itself is a feature of that interface, and it differs a little between the B7, B8 and B9 Series.
Before you start
- The Brainsalt Hub Desktop App is running and has discovered the server
- The server's BMC network port is connected — it is a separate socket from the server's normal network interfaces (all B7, B8 and B9 Series servers have a built-in BMC)
- The BMC's IP address is reachable from the computer running the Hub — the same subnet, or a route to it
- BMC credentials set under Settings → Credentials, or the factory credentials still in place
Steps
1. Select the server
Click the server row in the list. Its actions appear in the functions panel below the list (One window layout) or inline on the row (Separate windows layout). The BMC button is present whenever the Hub knows of a BMC for that server; its tooltip shows the controller's IP address.
The BMC address is not configured by hand. The Hub learns it from the server over the discovery channel and remembers it, so the button still works after the server has been switched off — the BMC runs on standby power.
2. Open the BMC web interface
Click BMC. The controller's web interface opens over HTTPS — as a tab beside the server list in One window layout, or in its own window in Separate windows layout. The Hub recognises which controller the server has and submits the matching credentials for you, so you land in the interface already signed in.
Clicking BMC again while that tab is in front closes it. Alt+← and Alt+→ (or the arrows on the tab strip) step back and forward, and F11 hides the Hub's header and sidebar so the interface fills the window.
3. Open the KVM console
Navigate to the KVM or remote-console section of that interface — the Hub does not jump there for you, and the wording differs between server families (typically Remote Control → KVM, iKVM or H5Viewer). From there you have full keyboard, video and mouse control of the server, including the BIOS and the boot sequence.
4. Close the session
Close the KVM window offered by the BMC interface first, then close the Hub's BMC tab or window. Leaving KVM sessions open holds a slot in the controller's small session table.
Options explained
BMC credentials live under ⚙ Settings → Credentials, one set per server family. The Hub picks the set matching the server it is talking to. Every set defaults to Same as User — untick that only when the controller genuinely needs its own account. All stored secrets are encrypted by the operating system's own credential protection.
|
Setting |
Description |
Values / Range |
|---|---|---|
|
BMC · B7 |
Credentials for the management controller in B7 Series servers. |
Username + password, or Same as User |
|
BMC · B8 |
Credentials for the management controller in B8 Series servers. |
Username + password, or Same as User |
|
BMC · B9 |
Credentials for the management controller in B9 Series servers. |
Username + password, or Same as User |
|
IP Config → IPMI / BMC |
The controller's own network: DHCP or a static address, plus an optional VLAN tag. Use this to bring an unreachable BMC onto your network. |
IPv4 addresses · VLAN 1–4094 |
Common Mistakes
-
The BMC button is amber and the interface does not load — the controller's address cannot be reached from this computer, usually because it sits on a VLAN or a foreign subnet. The server's own network being fine does not help. Correct the address under IP Config → IPMI / BMC, or move this computer onto the controller's network.
-
Nothing opens and the status line says no BMC was found — the controller's dedicated Ethernet port is not plugged in, or the server has never answered a BMC query. Connect the BMC port, then reselect the server.
-
The login page appears instead of the signed-in interface — the stored credentials do not match the controller. Check the set for the right family (B7 / B8 / B9) under Settings → Credentials; a set left on Same as User sends your server login, which the BMC does not know unless it was set up that way.
-
'Session limit reached', or the interface hangs — these controllers keep a very small session table, and force-closed browser or KVM sessions linger in it. Wait for the idle sessions to time out, or reset the controller from its own interface.
-
Power actions are offered but the sensor detail is thin — on some server families part of the management API sits behind a controller licence that is not activated. The Hub falls back to a safe default power menu; the missing detail needs that licence in place. Contact Brainsalt support.
Tips
-
The KVM console works while the operating system is down. Use it for BIOS settings, boot troubleshooting and reinstalling Windows remotely.
-
You rarely need the controller's own sensor pages — the Hub's health panel already reports temperatures, fans, voltages, power supplies and hardware errors for the selected server, refreshed continuously.
-
Chassis power does not need the BMC interface either: the ⏻ Power menu on the server row performs the controller's own reset actions, and the label shows the current power state.
-
Ctrl + and Ctrl − scale the Hub's interface if the controller's pages render small; the page inside the tab keeps its own zoom.
-
Keep the BMC network on your management LAN. It is a full out-of-band route into the server and should not sit on a public or guest network.
Related
Use the Brainsalt Hub Desktop App — the server list, per-server actions, health and power in full.
What is Brainsalt Hub? — how the desktop app, the on-server services and System Management fit together.
Control Server Power — power actions from the Hub and from System Management.
Monitor Server Health and Hardware Status — reading sensors, power supplies and hardware faults.